| Manufacturer of Architectural Standing Seam Roof Systems | |
CoolR™ products are made with 70% Kynar 500® or Hylar 5000® prepainted metal. These coatings are proven to last over 30 years with minimal maintenance. Warranties are offered with most applications.
Meets EPA Energy Star Products Program performance criteria. Available with high emissivity.
Armor-Clad Painted Metal Technical Specifications |
![]() |
|||
| Public Policy | Policy Requirements |
Minimum Initial Solar Reflectance |
Minimum Aged Solar Reflectance |
Mimimum Emittance |
| Energy Star | ||||
| Low slope (<2:12) | n/a | 0.65 | 0.5 | none |
| Steep slope (>2:12) | n/a | 0.25 | 0.15 | none |
| California Energy Code (Title 24) | ||||
| Required | 0.7 | none | 0.75 | |
| Florida State Energy Code | ||||
| Commercial | Required | 0.65 | none | 0.8 |
| Residential | Credit | 0.65 | none | 0.8 |
| Georgia Energy Code | ||||
| Credit | 0.7 | 0.75 | none | |
| Chicago Energy Concervation Code | ||||
| Low slope (<2:12) | Mandatory | 0.25 | 0.25 | none |
| Mod slope(2:12-5:12) | Mandatory | 0.15 | 0.15 | none |
| LEED | ||||
| Credit | 0.65 | 0.5 | 0.9 | |
| ASHRAE | ||||
| 90.1 Commercial | Credit | 0.7 | none | 0.75 |
| 90.2 Residential | 0.65 | none | 0.75 | |
| IECC | ||||
| Credit | 0.7 | none | 0.75 | |
| Canadian Energy Code | ||||
| Credit | none | none | none | |
| California State / Utility Cool Roof Rebate Programs | ||||
| Mandatory | 0.65 | 0.5 | none | |
Mandatory refers to policies where cool roofs must be used to comply. Required referes to policies where cool roofs are not mandatory, but an energy penalty Credit refers to policies where cool roofs are not mandatory, but an energy credit is earned if one is used. Source: Eley Associates, 2003 |
||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||